Keeler Direct Ophthalmoscope &LED Streak Retinoscope

Description

.KEELER  DIRECT OPHTHALMOSCOPE(2.8V).Model: Professional

Designed to ensure ultimate control of lenses, graticules and filters at the touch of a fingertip without the need to pull away from patient.

Technical Specification:-

  • Long lasting Xenon light with higher illumination, impressive diopter range +29D to -30D,
  • A quick step swing of +/- 20D helps to speed up the diagnosis.

Filter Aperture, graticules & filters:-

Wide Angle:- Illuminates the largest area of fundus for the best possible general diagnosis through a dilated pupil.

Intermediate:-Permits easier access through an undilated pupil and in peripheral examination.

Macular-Designed specifically for examination of the macular region of the fundus where a larger beam would create excessive Pupillary reaction or patient discomfort.

Slit:– Used primarily to determine retinal elevations & depressions but may also be used to assess anterior chamber depth.

Glaucoma– Project a graticule onto the retina to assess the optic cup / disc ratio as an aid to glaucoma diagnosis.

Fixation Cross:- Projects a graticule onto the retina for assessment of the degree & direction of eccentric fixation.

Red Free:-The red free filter is used to examine blood vessels in fine detail. By filtering out the red light, blood vessels are silhouetted black against a dark green background

Keeler LED Streak Retinoscope with rechargeable battery & charger

Optimised for outstanding performance with either a streak or spot halogen beam with a simple bulb change. Plus the new LED Professional Streak Retinoscope is now available.

Salient Features:-

Choice of illumination: Choose between 600lux of brilliant halogen illumination or the new LED Retinoscope. Whichever you choose, the professional guarantees you enough light to refract even the most difficult eyes.

New LED Professional Streak Retinoscope: Give you better contrast, image quality and longer battery life..

Netralisation check (Patented): The only Retinoscope allowing rapid confirmation of neutralisation. You can change the beam from divergent to convergent enabling you to cross check the accuracy of the neutral point, guaranteeing the assessment is correct every tiem.

Precision magnetic control (Patented): Improved 360⁰ access to a single control for both rotation and convergence adjustments. The precision movements are achived by use of rare earth magnet technology.

Two position aperture: A simple finger movement allows a choice of 4mm or 1.7mm aperture to optimize brightness or resolution of the retinal reflex.