Description
Fujitron Rebound Tonometer: FRT-200 – Accurate Intraocular Pressure Measurement
The Fujitron Rebound Tonometer: FRT-200 is designed for accurate and efficient intraocular pressure (IOP) measurement in children and adults. Combining rebound tonometry technology with a versatile measurement design, supports dependable IOP assessment across different clinical settings.
Powered by advanced algorithms, the device delivers precise IOP measurements, including in challenging conditions. Its measurement accuracy, convenient operation and wide measurement positioning make it suitable for hospitals, research institutes and home monitoring environments.
Key Features of Fujitron Rebound Tonometer FRT-200
1. Precision Algorithm and Reliable IOP Measurement
Deviation from Gold Standard: ≤1 mmHg (as stated in the feature section).
Accurate and stable measurement.
Comfortable IOP measurement without anaesthesia or air-puff stimulation.
Supports IOP assessment for glaucoma, ocular hypertension and elevated IOP.
2. 240° Measurement – Comprehensive Coverage
The FRT-200 supports multi-angle testing with a measurement range from horizontal to vertical, covering a total of 240°.
Supports supine, sitting and lying positions.
Suitable for patients with limited cooperation.
Supports 24-hour IOP monitoring.
Applicable for intraoperative measurement.
Rapid six-reading measurement with calculated average assessment.
3. User-Friendly, Single-Button Operation
Designed for convenient operation, the Fujitron FRT-200 completes IOP testing with a single button press.
Single-button IOP measurement.
Simplified measurement workflow.
Suitable for different user skill levels.
Easy operation for beginners and non-professional users.
4. Gentle Contact and Enhanced Patient Comfort
Using rebound tonometry technology, the probe lightly touches the corneal surface with almost no pressure.
Momentary, harmless probe contact.
Disposable, individually packed probes.
Easy probe loading.
Designed to eliminate the risk of cross-infection through disposable probes.
Accurate readings displayed to one decimal mmHg resolution.
5. Measurement Guidance and Data Storage
The device provides feedback on probe distance, indicating whether the probe is too far or too close, and assists with data quality assessment.
Measurement guidance through probe-distance feedback.
Historical data storage of 100 data sets.
Differentiates between left and right eyes.
Clinical Applications
The Fujitron FRT-200 is designed for multiple IOP measurement and monitoring environments.
Outpatient services: Routine IOP measurements, particularly for adult and paediatric patients who cannot cooperate with NCT.
24-hour IOP monitoring: Supports supine measurements and IOP monitoring, including for normal-tension and glaucoma patients.
Home monitoring: Supports intraoperative and post-operative follow-up, including clinician-directed IOP checks during post-operative care.
Why Choose Fujitron FRT-200?
Flexible Measurement Positioning: Supports IOP measurement across a 240° range, from horizontal to vertical positions.
Comfortable Measurement: Rebound technology enables gentle probe contact with the corneal surface, without air-puff stimulation.
Efficient Clinical Workflow: Single-button operation and rapid six-reading measurement with calculated average assessment.
Reliable Data Management: Stores up to 100 measurement data sets, with separate differentiation between left and right eyes.
The Fujitron Rebound Tonometer combines rebound tonometry technology, flexible measurement positioning and convenient operation in one device. Its wide measurement range, precise display resolution and historical data storage support efficient intraocular pressure assessment.
For hospitals, eye clinics and healthcare institutions looking for a rebound tonometry solution, the FRT-200 offers a versatile approach to IOP measurement. The product is supplied by Mediscience Devices.
Technical specifications
Specification | Details |
|---|---|
Product Name | Fujitron Rebound Tonometer: FRT-200 |
Indications for Use | Intraocular pressure measurement for children and adults |
Measurement Range | 5.0–70.0 mmHg |
Display Resolution | 0.1 mmHg |
Measurement Accuracy | ±1.0 mmHg (IOP ≤20 mmHg); ±1.7 mmHg (IOP >20 mmHg), vs. Goldmann Tonometer |
Measurement Position | Horizontal to Vertical (240° total) |
Measurement Guidance | Provides feedback on probe distance (too far/too close); assists in data quality assessment |
Power Supply | 4 AA alkaline batteries |
Historical Data Capacity | Stores 100 data sets, differentiating between left and right eyes |