Description
Mars Medica Digital Auto Lensmeter MAL-100 for Optical Shops, Eye Clinics & Lens Laboratories
Mediscience offers the Mars Medica Digital Auto Lensmeter MAL-100, a professional lens measurement and verification system designed for optical shops, lens laboratories, optometry practices and ophthalmic facilities.
The MAL-100 provides digital measurement of sphere, cylinder, axis, addition and prism, covering a broad range of prescription lens requirements. It supports single-vision and progressive-lens workflows, with dedicated PD measurement functions for monocular PD, single-vision PD and progressive-lens far-vision PD.
A 7-inch tiltable colour touchscreen provides a clear operating interface, while the built-in thermal printer allows measurement results to be documented directly at the instrument. The RS232/Bluetooth interface provides additional connectivity for compatible digital workflows.
The MAL-100 also incorporates a maintenance-free ink-cartridge marking system, helping optical professionals mark lenses during the verification and dispensing process without relying on a conventional replaceable ink system.
With a compact footprint and approximately 5 kg weight, the MAL-100 is suitable for professional dispensing environments where accurate lens measurement, marking and documentation need to be combined in one workstation.
Key Features
- Digital auto lensmeter for professional lens measurement
- Sphere measurement from -25.00D to +25.00D
- Cylinder measurement up to ±10.00D
- Addition measurement up to +10.00D
- Prism measurement up to 20△
- Multiple measurement-step options
- Supports minus, plus and mixed cylinder modes
- X-Y and P-R prism measurement modes
- Monocular and progressive-lens PD measurement
- 7-inch tiltable colour touchscreen
- Built-in thermal printer
- Maintenance-free ink cartridge marking system
- RS232 and Bluetooth connectivity
- 535 nm green measurement wavelength
- Compact desktop design
- Suitable for optical and ophthalmic professional workflows
Applications
The Mars Medica MAL-100 can support:
- Prescription lens verification
- Optical lens dispensing
- Single-vision lens measurement
- Progressive lens measurement
- Lens power verification
- Cylinder and axis verification
- Addition measurement
- Prism measurement
- Monocular PD measurement
- Progressive-lens far PD measurement
- Finished lens inspection
- Optical shop workflows
- Lens laboratory operations
- Optometry practices
- Ophthalmic optical dispensing centres
Why Choose the Mars Medica Digital Auto Lensmeter, Model: MAL-100 from Mediscience?
The MAL-100 combines lens measurement, marking, PD assessment, printing and connectivity in a single professional workstation. This makes it suitable for optical businesses that need more than basic lens-power verification.
Its broad measurement range covers common prescription parameters, while the selectable measurement increments provide flexibility for different lens-verification requirements. The built-in thermal printer can simplify documentation, while RS232 and Bluetooth provide options for connecting the lensmeter with compatible systems.
The dedicated progressive-lens far PD measurement function is also useful for optical dispensing workflows that require accurate pupillary-distance information alongside lens verification.
Mediscience supplies optical and ophthalmic equipment for optical retailers, lens laboratories, eye clinics, optometry practices and institutional healthcare buyers, with B2B procurement support.
| Technical Specification | ||
|---|---|---|
| Features | MAL-100 | |
| Measurement range | Sphere | -25.00 to +25.00 D (Step: 0.01/ 0.06/ 0.12/ 0.25 D) |
| Cylinder | 0 to +- 10.00 D (Step: 0.01/ 0.06/ 0.12/ 0.25 D) | |
| Axis | 0 to 180* (Step: 1*) | |
| ADD | 0 to + 10.00 D (Step: 0.01/ 0.06/ 0.12/ 0.25 D) | |
| Prism | 0 to 20 (0.01/ 0.06/ 0.12/ 0.25) | |
| Measurement mode | Measurable lens diameter | 10 to 90 mm |
| Cylinder | -, MIX, + | |
| Prism | X-Y, P-R | |
| P.D measurement | 20.0 to 45.0mm (monocular), Single vision PD, Progressive lens far vision PD | |
| Wave length/ Measuring point | 535 nm (green)/ 108 within nosepiece | |
| Display | Tiltable 7.0 inch color LCD touch screen | |
| Marking system | Maintenance free ink cartridge type | |
| Printer | Built-in Thermal Printer | |
| Interface | RS232/Bluetooth | |
| Power Supply | 100~240 VAC / 50~60Hz. | |
| Dimensions | 255 (W) × 224 (D) × 434 (H) mm | |
| Weight | Approx 5.0 kg | |
| Power Consumption | 35w maximum | |
Frequently Asked Questions
A digital auto lensmeter is used to measure and verify prescription lenses. It can determine parameters such as sphere, cylinder, axis, addition and prism before lenses are dispensed.
Yes. The MAL-100 supports progressive-lens measurement workflows and includes progressive-lens far-vision PD measurement.
Yes. The instrument provides prism measurement using X-Y and P-R modes, with a specified measurement range up to 20△.
Pupillary distance helps position the optical centre of a spectacle lens appropriately in relation to the wearer's pupils. Accurate PD measurement is therefore an important part of spectacle dispensing.