Description
PlusOptix Portable Autorefractometer A12R for Pediatric Eye Screening & Ophthalmology Practices
Mediscience offers the PlusOptix A12R Portable Autorefractometer, a compact binocular photorefraction system designed for mobile eye examinations, pediatric screening, optometry practices and ophthalmic entry examinations.
The A12R is designed to obtain binocular measurements from approximately 1 metre away, allowing the operator to assess both eyes simultaneously without requiring the patient to be positioned directly against a conventional tabletop autorefractor. PlusOptix identifies the A12R specifically as a mobile binocular autorefractor for use across multiple examination rooms and locations.
Its rapid measurement workflow takes an average of approximately 0.5 seconds, while the integrated touchscreen provides direct access to the device interface. Battery operation further supports use in mobile screening environments where a fixed power connection may not be convenient.
The A12R is particularly relevant to school-entry examinations, pediatric vision screening and mobile eye-care workflows. PlusOptix states that its binocular autorefractors measure sphere, cylinder and axis of both eyes simultaneously from one metre.
Key Features
- Portable binocular autorefractometer
- Simultaneous measurement of both eyes
- Designed for measurement from approximately 1 metre
- Rapid acquisition in an average of 0.5 seconds
- Sphere and cylinder measurement
- Pupil-size measurement
- Warble-sound fixation target
- 4.3-inch touchscreen display for A12R
- Battery-powered operation using 6 × AA batteries
- SD card and USB connectivity
- Compact handheld/mobile design
- Suitable for pediatric and mobile eye-screening workflows
- CE and FDA certification according to the supplied specifications
PlusOptix identifies the A12R as a mobile model intended for use across multiple examination rooms and locations, with results documentable electronically or on paper.
Important specification note: The supplied table contains both A12C and A12R columns, with some values shown only under A12C. For the website copy above, I have retained the A12R-specific information where the manufacturer documentation clearly supports it. The official PlusOptix comparison lists the A12R with a 4.3-inch resistive touchscreen, 2 × USB, SD and 6 × rechargeable AA batteries, while the A12C has the larger 5.7-inch screen and WLAN.
Applications
The PlusOptix A12R can support:
- Pediatric vision screening
- School-entry vision examinations
- Mobile eye screening
- Community eye-care programs
- Pediatric ophthalmology practices
- Optometry screening
- Preliminary refractive assessment
- Ophthalmic entry examinations
- Screening across multiple examination rooms
- Eye camps and outreach programs
- Primary eye-care environments
PlusOptix specifically positions its binocular autorefractors for obtaining a reliable baseline refraction during an entry examination, while its A12R is described as suitable for mobile use across multiple examination rooms.
Why Choose the PlusOptix A12R from Mediscience?
The PlusOptix A12R is designed around mobility. Instead of requiring a fixed tabletop setup, the device allows measurements to be performed from approximately one metre away, making it practical for environments where children or patients may be difficult to position on conventional equipment.
Its binocular measurement approach captures information from both eyes simultaneously, while the rapid acquisition time can help streamline high-volume screening workflows. PlusOptix states that its binocular autorefractors use infrared photorefraction technology and that measurements can be obtained from one metre in less than a second.
The A12R also provides documentation options through its SD card and optional compatible printing workflow. PlusOptix specifically identifies the model as an option where direct EMR connectivity is not required.
Mediscience supplies ophthalmic diagnostic and screening equipment for hospitals, eye clinics, pediatric practices, optometrists, screening programs and institutional healthcare buyers, with B2B procurement support.
| Technical Specifications: | ||
|---|---|---|
| Measurement | A 12C | A 12R |
| Sphere*) | -7,0/+5,0 dpt in 0,25 dpt steps | |
| Cylinder*) | -7,0/+5,0 dpt in 0,25 dpt steps | |
| Pupil size | 4,0 -8,0 mm in 0,1 mm steps | |
| Acquisition time | dynamic, in average 0,5 sec. | |
| Measuring distance | 1 meter (+/- 5cm) | |
| Fixation target | Warble sound | |
| Technical data | ||
| Monitor resolution | 5,7” | 4,3” |
| Touch Screen | Touch Screen | |
| Interfaces | 2 x USB, 1 x SD-Card (WLAN) | 2 x USB, 1 x SD-Card |
| Voltage | 100-120V / 220-240 VAC | |
| Frequency | 50 – 60 Hz | |
| Battery operation | 6 x AA | |
| Certified | EN 60601, CE and FDA | |
Frequently Asked Questions
A conventional autorefractor generally uses a fixed examination position, while the A12R is a mobile, handheld binocular system designed to measure from approximately one metre. This makes the A12R particularly practical for pediatric screening, outreach and examinations across multiple locations.
Yes. PlusOptix states that A12R measurement results can be documented electronically or on paper, with SD-card-based documentation available.
Yes. The A12R supports battery operation, making it suitable for mobile screening and examination locations where direct mains power may not be convenient. The official comparison lists six rechargeable AA-size batteries for the A12R.
The device can measure from approximately one metre away rather than requiring the child to be positioned against a tabletop instrument. PlusOptix specifically positions its mobile binocular autorefractors for pediatric and school-entry screening environments.
