Description
3 Nethra Fundus Camera for Hospitals, Eye Clinics & Telemedicine
Mediscience offers the 3 Nethra Fundus Camera, a professional retinal imaging system designed for hospitals, ophthalmology clinics, eye-care centres, screening programmes and telemedicine applications. With a 45° field of view, 6.4-megapixel imaging and 8–14 micron optical resolution, the 3 Nethra provides high-resolution fundus photography for routine retinal imaging and documentation.
The 3 Nethra Fundus Camera supports non-mydriatic imaging along with multifunctional imaging capabilities covering the posterior and anterior segments as well as dry-eye imaging. Its compatibility with multiple AI systems and telemedicine platforms makes it particularly suitable for modern eye-care facilities looking to integrate retinal imaging into digital screening and remote-care workflows.
For hospitals, eye clinics and ophthalmology practices looking for a fundus camera in India, the 3 Nethra combines compact construction, low DC power consumption and high-resolution digital imaging in a professional ophthalmic imaging solution.
Key Features
- Professional 3 Nethra Fundus Camera
- 45° field of view for retinal imaging
- Optical resolution of 8–14 microns
- High-resolution 6.4-megapixel camera
- Non-mydriatic imaging capability
- Multifunctional imaging
- Posterior and anterior imaging
- Dry-eye imaging capability
- Compatible with multiple AI systems
- Compatible with telemedicine platforms
- Compact and relatively lightweight configuration
- Low 5–10 W DC power consumption
- US-FDA cleared
- CE marked
- Health Canada registered
Advanced Retinal Imaging
The 3 Nethra Fundus Camera is designed to provide high-resolution digital imaging of the eye for professional ophthalmic examination and documentation. Its 45-degree field of view provides a broad retinal imaging area, while the 6.4-megapixel camera supports detailed digital image capture.
With 8–14 micron optical resolution, the system is suited to facilities requiring high-quality retinal images for clinical assessment, documentation and screening workflows.
Non-Mydriatic & Multifunctional Imaging
A major advantage of the 3 Nethra Fundus Camera is its multifunctional imaging capability. The system supports:
- Non-mydriatic fundus imaging
- Posterior segment imaging
- Anterior segment imaging
- Dry-eye imaging
This makes the device more versatile than a fundus camera intended solely for conventional retinal photography, allowing it to support multiple imaging requirements within an eye-care facility.
AI & Telemedicine Compatibility
The 3 Nethra is compatible with multiple AI systems and telemedicine platforms, making it suitable for digitally connected ophthalmology and remote eye-screening workflows.
For hospitals and eye-care organisations implementing AI-assisted retinal screening, teleophthalmology or telemedicine programmes, this connectivity can help integrate fundus imaging into broader digital healthcare systems.
Applications
The 3 Nethra Fundus Camera is suitable for:
- Ophthalmology hospitals
- Eye hospitals
- Ophthalmology clinics
- Eye-care centres
- Retinal imaging departments
- Diabetic eye screening programmes
- Ophthalmic screening centres
- Telemedicine and teleophthalmology
- AI-assisted retinal screening
- Mobile and community eye-screening programmes
Why Choose 3 Nethra Fundus Camera from Mediscience?
For organisations searching for a fundus camera, retinal camera, non-mydriatic fundus camera or ophthalmic imaging equipment, the 3 Nethra Fundus Camera provides a multifunctional imaging platform with high-resolution digital imaging and compatibility with AI and telemedicine systems.
Its combination of 45° field of view, 6.4MP imaging, non-mydriatic functionality and multifunctional eye imaging makes it a suitable solution for hospitals, clinics and screening programmes seeking to expand their digital ophthalmic imaging capabilities.
Mediscience supplies professional ophthalmic equipment for hospitals, eye clinics, ophthalmology practices and institutional healthcare requirements. Contact Mediscience to enquire about 3 Nethra Fundus Camera pricing, availability and B2B supply.
Technical Specifications:-
| Model | 3 Nethra fundus Camera |
|---|---|
| Field of view | 45 degrees |
| Optical resolution | 8-14 microns |
| Dimensions | 520 mm (H) X 420 mm (L) X 400 mm (W) |
| Weight | 11.1 kgs (3.4 kgs tricam + 7.7 kgs stand) |
| Power consumption | 5-10 W (DC) |
| Imaging | Non-mydriatic imaging, multi-functional imaging, posterior, anterior, and dry eye |
| Imaging quality | High-resolution 6.4 megapixel camera |
| Compatibility | Compatible with multiple AI systems and telemedicine platforms |
| Regulatory compliance | US-FDA cleared, CE marked, and Health Canada registered |
Frequently Asked Questions
Yes. The specifications include non-mydriatic imaging, allowing it to be used for retinal imaging workflows without routine pharmacological pupil dilation.
The 3 Nethra uses a 6.4-megapixel camera for high-resolution digital imaging.
Yes. In addition to posterior imaging, the system supports anterior imaging and dry-eye imaging.
Yes. The system is specified as compatible with multiple AI systems, making it suitable for AI-integrated retinal screening workflows.